Comparison of hemoglobin values obtained by arterial blood gas analysis versus laboratory method during major head-and-neck surgeries


1 Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
2 Department of Anaesthesia, Netaji Subhas Medical College and Hospitals, Patna, Bihar, India

Correspondence Address:
Dr. Sunil Rajan
Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aer.aer_67_22

Rights and Permissions

Background: Accuracy of hemoglobin (Hb) measured by arterial blood gas (ABG) analyzer is considered inferior to laboratory (lab) measurements as it could overestimate Hb levels. Aim of the Study: The study aims to compare Hb measured using ABG versus conventional lab method at the time of major blood loss and in the preoperative and immediate postoperative periods. Settings and Design: It was a prospective, nonrandomized observational study conducted in a tertiary care center. Materials and Methods: The study was conducted in 24 patients undergoing major head-and-neck surgeries. Simultaneous blood samples were sent for Hb measurement by ABG analysis and lab method at induction of anesthesia, when intraoperative blood loss exceeded maximum allowable blood loss, and in the immediate postoperative period. Statistical Analysis Used: Chi-square test, independent sample's t-test, and paired t-test were used for statistical analysis. Results: Mean Hb values obtained by both techniques were significantly different at all time points. Hb obtained by ABG analysis was significantly higher than lab value preoperatively (12.78 ± 2.51 vs. 12.05 ± 2.2, P = 0.038), at maximum blood loss (11.00 ± 2.57 vs. 9.87 ± 2.06, P = 0.006), and in the immediate postoperative period (11.96 ± 2.00 vs. 10.96 ± 2.24 P < 0.001). ABG Hb values were found to be approximately 1 g.dL−1 greater than lab values. Conclusion: Hb measured by ABG analysis was significantly higher than that measured by lab method at the time of major blood loss, preoperatively, and at the immediate postoperative period in patients undergoing major head-and-neck surgeries, with a good correlation of values obtained by both the techniques.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed440    
    Printed12    
    Emailed0    
    PDF Downloaded32    
    Comments [Add]    

Recommend this journal